 Description

Introduction To recirculating Recirculating Chiller For Rotary Evaporator  


Recirculating Chiller For Rotary Evaporator is a low-temperature liquid circulation equipment that adopts mechanical refrigeration to provide stable low-temperature cooling liquid circulation. It can be matched with various instruments (rotary evaporator, fermentation tank, chemical reaction kettle, freeze-drying equipment, biological Pharmaceutical reaction kettle, etc.); large cooling capacity, fast cooling speed, greatly improving work efficiency. The equipment pumps and circulates the low-temperature coolant to the equipment or system that needs cooling through electric drive. The Recirculating Chiller For Rotary Evaporator absorbs heat by circulating the coolant, cools the coolant again and sends it back to the system to maintain a stable low temperature state of the equipment or system.

recirculating chiller for rotary evaporator component

Advantages Of Recirculating Chiller For Rotary Evaporator


Precise Temperature Control:


The Recirculating Chiller For Rotary Evaporator  allows for precise temperature control, ensuring accurate and stable cooling performance. It enables users to set and maintain the desired low-temperature level, providing consistent cooling to the target equipment or system.


Reliable Low-Temperature Cooling:


These pumps are specifically designed to provide reliable low-temperature cooling. They can handle low-temperature coolant, such as ethylene glycol-water mixture, liquid nitrogen, or liquid argon, and circulate it effectively to maintain the desired low temperature. This ensures that the equipment or system operates within the required temperature range.


High Cooling Efficiency:


The Recirculating Chiller For Rotary Evaporator  is engineered for high cooling efficiency. It has a powerful circulation capability, quickly delivering the low-temperature coolant to the target equipment or system. This efficient cooling process helps achieve the desired low-temperature levels promptly and maintains them consistently.


Adjustable Flow Rate:


The pump allows for adjustable flow rate control, allowing users to regulate the flow of the coolant according to the specific cooling requirements of the equipment or system. This flexibility ensures optimal cooling performance and energy efficiency, as the flow rate can be tailored to meet the cooling demands accurately.


Compact and Space-Saving Design:


The Recirculating Chiller For Rotary Evaporator  is compact in size, occupying minimal space in the laboratory or industrial setup. Its space-saving design allows for easy integration into existing systems or installation in tight spaces.

recirculating chiller for rotary evaporator detail
 


Application Of Recirculating Chiller For Rotary Evaporator


Chemical and Pharmaceutical Industries:


The pump is widely used in chemical synthesis, pharmaceutical manufacturing, and other related industries. It provides precise and reliable low-temperature cooling for reactions, distillation, condensation, and other processes that require controlled temperature environments.


Laboratory Research:


In laboratory settings, the Recirculating Chiller For Rotary Evaporator  is utilized in various scientific disciplines. It is commonly used in chemistry, biology, biochemistry, and material science research for maintaining low temperatures during experiments, sample storage, or specialized equipment cooling.


Medical and Healthcare:


The pump is employed in medical and healthcare settings for low-temperature applications. It can provide cooling for medical equipment, such as laser systems, magnetic resonance imaging (MRI) machines, and cryosurgery devices, ensuring their optimal functioning and safety.


Aerospace and Automotive Industries:


The Recirculating Chiller For Rotary Evaporator  is utilized in aerospace and automotive industries for cooling applications. It helps maintain stable low temperatures in testing chambers, wind tunnels, engine components, and other specialized systems.

recirculating chiller for rotary evaporator application


Maintenance Of Recirculating Chiller For Rotary Evaporator


Regular cleaning:


Regular cleaning of the Recirculating Chiller For Rotary Evaporator and system is key to maintaining its consistent performance. Remove accumulated dust, dirt and other impurities to ensure cooling efficiency and proper system ventilation. Use proper cleaners and tools, following manufacturer's recommendations.


Check and replace seals:


Regularly inspect the seals of the Recirculating Chiller For Rotary Evaporator, such as seal rings and gaskets, to ensure their integrity and tightness. If any wear, aging or damage is found, replace it in time to prevent leakage and performance degradation.


Lubrication and lubricant change:


Moving parts and bearings in the Recirculating Chiller For Rotary Evaporator may require periodic lubrication. Use the proper lubricant, according to the manufacturer's recommendations, and change the lubricant regularly to ensure proper operation of the equipment and reduce wear.


Electrical inspection:


Regularly check the electrical connections of the Recirculating Chiller For Rotary Evaporator to ensure that the power cord is securely connected and well insulated. Check the working condition of electrical components and control systems, and repair or replace damaged electrical components.


To clean the condenser and radiator:


The condenser and radiator in the Recirculating Chiller For Rotary Evaporator are an important part of heat exchange. Regularly clean the surface of the condenser and radiator to ensure good heat dissipation and avoid overheating and reduced cooling efficiency.


Regular calibration and testing:


Regularly calibrate and test the Recirculating Chiller For Rotary Evaporator to ensure its temperature control and performance meet the requirements. Use thermometers and other test equipment for accurate measurements and verifications.

recirculating chiller for rotary evaporator parameter

 Parameter

Model DLSB 10L-10℃ DLSB 10L-20℃ DLSB 10L-30℃ DLSB 10L-40℃ DLSB 10L-60℃ DLSB 10L-80℃
Storage
Volume
10L
Low temperature range -10℃~RT -20℃~RT -30℃~RT -40℃~RT -60℃~RT -80℃~RT
Temperature stability ±2℃
Refrigeration capacity 520~1320W 980~1320W 120~1320W 280~3580W 850~3800W 270~2850W
Rated Power 980W 980W 980W 1850W 4225W 2200W
Voltage 220V 50Hz
Max. Input Current 4.8A 4.8A 5.2A 11.5A 20A 13A
Flow 20 L/min 50 L/min 20 L/min 25 L/min 25 L/min 20 L/min
Lift 4~6 m 4~6 m 6 m 10~12 m 10~12 m 10~12 m

 FAQ

Q: Recirculating Chiller For Rotary Evaporator won't start or has no output.


A: Check whether the power connection is correct, make sure the power cord is firmly connected and the power supply is normal.
Check if a motor protection device has tripped, such as an overload protector or thermal protector, wait for it to cool down and reset.
Check the motor for faults such as damaged windings or circuit boards that require repair or replacement of the motor.


Q: The cooling effect of the cryopump is reduced or there is no cooling.


A: Check whether the cooling system has enough cooling medium, such as coolant or cooling gas, and add or replace it in time.
Check the cooling system pipeline for blockage or blockage, clean or unclog the pipeline.
Check the cooler or radiator surfaces for accumulated dirt or blockages and clean them.
Check whether the circulation pump of the cooling system is working normally, check the state of the pump and the lubrication condition.


Q: The Recirculating Chiller For Rotary Evaporator is leaking or has a bad seal.


A: Check whether the sealing gaskets or sealing rings of the pump body and pipeline connection parts are intact, and replace worn or damaged seals.
Check the seal between the pump body and the pump shaft, replace worn or damaged seals.
Check the shaft seals of the pump body and pump shaft to ensure that they are well sealed, and replace damaged shaft seals.

Request For Quotation

You can get the price list and we will contact you within one working day.

Contact Supplier Get Latest Price